Standar CCSI
Spesifikasi Teknis
GENERAL

The cable is applicable for indoor, on cable trays/ ladders including underground installation and inside conduits.

REFERENCE STANDARDS

The offered fiber optic cable complies to the ITU-T G.652.D, ITU-T G.657.A1, IEC 60794, TIA/ EIA standards.

CONSTRUCTIONS
CABLE STRUCTURE
Fully waterblocked cable

– Each fibers are inserted into thixotropic gel-filled coloured thermoplastic (PC-PBT) loose buffer tubes

– Water ingression protection

Central loose tube design

– Single loose tube

Anti-Rodent material

– Provides rodent bite protection

Low Smoke Zero Halogen Flame Retardant (LSZH FR) Jacket

– Black UV resistant Low Smoke Zero Halogen Flame Retardant (LSZH FR) sheath as outer protection

– The thermoplastic sheath does not promote the growth of fungus and be free of pits, splits and blisters

– Reduces the amount of toxic and corrosive fume emission

– Other sheathing are available upon request

PARAMETERS
FIBER PARAMETERS OF SINGLE MODE OPTICAL FIBER :
Reference Standard ITU-T G.652.D

Type

Bending-Loss Insensitive
Single Mode

Wavelength (nm)

1310 / 1550

Attenuation on Finished Cables (dB/km)

0.35 / 0.20

Typical Attenuation (dB/km)

0.35 / 0.19

Mode Field Diameter (µm)

9.2 ± 0.4 / 10.4 ± 0.5

FIBER PARAMETERS OF MULTIMODE OPTICAL FIBER :
Core / Cladding Diameter (µm) 50/125 62.5/125

Reference Standard

ITU-T G.651.1

TIA – EIA – 568 – B.3

Wavelength (nm)

850 / 1300

850 / 1300

Attenuation on Finished Cables (dB/km)

3.0 / 0.8

3.5 / 1.5

Modal Bandwidth – length product for overfilled launch (MHz.km)

500 / 500

160 / 500

Multimode OM3 and OM4 fibers are available upon request.

CABLE PARAMETERS :
ITEM SPECIFICATION

Fiber Quantity

4

Loose Tube Quantity

1

Cable Dimension Oter Diameter (Nominal)

6.0 mm

Cable Dimension Weight (Nominal)

45 kg/km

MECHANICHAL CHARACTERISTICS :
ITEM SPECIFICATION

Operating Tensile Strength (Refer to IEC 60794-1-E1)

1000 N

Crush Strength (Refer to IEC 60794-1-E3)

1000 N/ 250 mm

Impact Strength (Refer to IEC 60794-1-E4)

5 Nm

Kink Strength (Refer to IEC 60794-1-E11)

5 x Cable Outside Diameter

Minimum Bending Radius (Refer to IEC 60794-1-E11)

10 x Cable Outside Diameter

Water Ingression Resistance (Refer to IEC 60794-1-F5B)

Passed with 1-m cable sample, 24 hours,1-m water column height pressure

Operating & Storage Temperature

Up to 70° C

Download Product Catalog

Kami akan mengirimkan katalog produk ke email Anda,
silahkan mengisi alamat email Anda

Scroll to Top