Kabel Duct Metallic, Standar CCSI
Spesifikasi Teknis
GENERAL

The cable is for outdoor, underground inside HDPE ducts. The installation may use air-assisted (air-blown) method, water pressure-floating or manual pulling.

REFERENCE STANDARDS

The offered fiber optic cable complies to the the ITU-T G.652.D, ITU-T G.654.B, ITU-T G.654.C, ITU-T G.655.C, ITU-T G.655.D, ITU-T G.657.A1, IEC 60794-3, TIA/ EIA standards. Fiber type is optional, following to the customer request.

CONSTRUCTIONS
CABLE STRUCTURE
Fully waterblocked cable

– Each fibers are inserted into thixotropic gel-filled coloured dual-layer thermoplastic (PC-PBT) loose buffer tubes

– Water ingression protection is applied using swellable compound and tape

Dielectric central strength member

– Requires no grounding

– More flexible

– Glass reinforced plastic (GRP/FRP) non-metallic, anti buckling central strength element

Corrugated Steel Tape Armor

– Provides rodent bite protection for direct buried applications

High Density Polyethylene (HDPE) Jacket

– Black UV resistant High Density Polyethylene (HDPE) jacket as outer protection

– Good abrasion & scratch resistance

 – Excellent weathering and UV resistance

PARAMETERS
FIBER PARAMETERS OF SINGLE MODE OPTICAL FIBER :
Reference Standard ITU-T G.652.D ITU-T G.654.B ITU-T G.654.C ITU-T G.655.C & 655.D ITU-T G.657.A1

Type

Single Mode

Cut-Off Shifted Single Mode

Non-Zero Dispersion Shifted
(NZDSF) Single Mode

Bending-Loss Insensitive
Single Mode

Wavelength (nm)

1310 / 1550

1550

1550

1550 / 1625

1310 / 1550

Attenuation on Finished Cables (dB/km)

0.35 / 0.20

0.180

0.180

0.215 / 0.35

0.35 / 0.20

Typical Attenuation (dB/km)

0.35 / 0.19

0.175

0.175

0.210 / 0.35

0.35 / 0.19

Mode Field Diameter (µm)

9.2 ± 0.4at 1310 nm

11.9 ± 0.5at 1550 nm

9.9 ± 0.5at 1550 nm

9.6 ± 0.4at 1550 nm

9.2 ± 0.4at 1550 nm

FIBER PARAMETERS OF MULTIMODE OPTICAL FIBER :
Core / Cladding Diameter (µm) 50/125 62.5/125

Reference Standard

ITU-T G.651.1

TIA – EIA – 568 – B.3

Wavelength (nm)

850 / 1300

850 / 1300

Attenuation on Finished Cables (dB/km)

3.0 / 0.8

3.5 / 1.5

Modal Bandwidth – length product for overfilled launch (MHz.km)

500 / 500

160 / 500

Multimode OM3 and OM4 fibers are available upon request.

CABLE PARAMETERS :
ITEM SPECIFICATION

Fiber Quantity

4 – 30

12 – 60

72

84 – 96

108 – 144

156 – 216

228 – 312

Maximum Fibers per Tube

6

12

12

12

12

12

12

Loose Tube Quantity

5

5

6

8

12

18

26

Number of Active Tubes

1 – 5

1 – 5

6

7 – 8

9 – 12

13 – 18

19 – 26

Cable Dimension Cable Diameter (Nominal)

9.0 mm

9.5 mm

10.0 mm

11.5 mm

14.0 mm

14.5 mm

17.5 mm

Cable Weight (Nominal)

60 kg/km

65 kg/km

80 kg/km

100 kg/km

130 kg/km

160 kg/km

230 kg/km

MECHANICHAL CHARACTERISTICS :
ITEM SPECIFICATION

Operating Tensile Strength (Refer to IEC 60794-1-E1)

2900 N

Crush Strength (Refer to IEC 60794-1-E3)

2500 N/ 100 mm

Impact Strength (Refer to IEC 60794-1-E4)

12 Nm

Kink Strength (Refer to IEC 60794-1-2-E10)

5 x Cable Outside Diameter

Minimum Bending Radius (Refer to IEC 60794-1-E11)

10 x Cable Outside Diameter

Torsion (Refer to IEC 60794-1-E7)

30 twists, 2 direction @ 180Ëš, Load 250N

Water Ingression Resistance (Refer to IEC 60794-1-F5B)

Passed with 1-m cable sample, 24 hours,1-m water column height pressure

Operating & Storage Temperature

Up to 70° C

Download Product Catalog